Menu
OPEN HOME AUTOMATIONCOMPONENTS · AGENT SKILLS · YOUR OWN PROJECTAPACHE-2.0 ↗
← DOMOSENSO / FRAMEWORK

HARDWARE / SETUP GUIDE

M5Stack Unit CO2L

One room's CO2 reading on the Ramka's Air page, and a printable dragon stand for the sensor and its Atom Lite.

All hardware
Documented component versionsView pinned hardware source ↗

Follow the instructions for this exact model and role. Compatibility with other models is not implied.

M5Stack Unit CO2L: wiring, firmware and enclosure

M5Stack's Unit CO2L (SKU U104) is a Sensirion SCD41 photoacoustic CO₂ sensor that also reads temperature and humidity. It comes with a 20 cm Grove cable and hangs from an M5Stack Atom Lite, which reports it to Home Assistant over ESPHome. One unit gives one room a CO₂ reading, and the Ramka shows that room on its Air page (SPEC-042). Device file: m5stack-unit-co2l.yaml.

Wiring

Plug the unit's Grove cable into the Atom Lite's Grove port. It needs no other wiring.

Atom Lite Grove pinsignalESPHome
5Vpower (the unit regulates to 3.3 V)
Gground
G26I²C SDAsda: GPIO26
G32I²C SCLscl: GPIO32

Keep the unit at the end of its cable, away from the Atom. The Atom's warmth raises the unit's own temperature reading.

Firmware

The catalog has no package for the unit yet. Add this to the Atom's ESPHome device file, next to whatever the node already runs (a bermuda-presence proxy, for example):

substitutions:
  altitude: 300m   # the room's height above sea level, for the pressure compensation

i2c:
  id: grove_i2c
  sda: GPIO26
  scl: GPIO32

sensor:
  - platform: scd4x
    id: co2_unit
    i2c_id: grove_i2c
    altitude_compensation: ${altitude}
    automatic_self_calibration: true
    update_interval: 60s
    co2:
      name: CO2
    temperature:
      name: CO2 unit temperature
      disabled_by_default: true   # the unit's own air, warmed by the Atom
    humidity:
      name: CO2 unit humidity
      disabled_by_default: true

api:
  actions:
    - action: calibrate_co2
      variables:
        co2_ppm: int
      then:
        - scd4x.perform_forced_calibration:
            value: !lambda 'return co2_ppm;'
            id: co2_unit

Name the CO₂ entity in the Ramka's air input as one room, for example {label: Bedroom, room: bedroom, co2: sensor.<node>_co2}. With climate-air 0.3.1 or later, the room's air: {co2: sensor.<node>_co2} in the home inputs adds the CO₂ limits (fair and poor), which the Ramka settings dashboard changes.

After the first start

  • Accuracy (Sensirion datasheet): ±(50 ppm + 2.5 %) up to 1000 ppm and ±(50 ppm + 3 %) up to 2000 ppm; specified to 5000 ppm.
  • Self-calibration: it assumes the room reaches outdoor air, about 425 ppm, once a week. Treat the first week's readings as provisional.
  • A room that is never aired: set automatic_self_calibration: false and calibrate by hand a few times a year. Run the unit for 3 minutes at a wide-open window, then call the node's calibrate_co2 action with co2_ppm: 425.

Enclosure

The dragon stand closed: a dark figure of a dragon sitting on a rock, the sensor in its openwork head with gill slots, a wing on each side and the plunger's window in the rockOpen full-size image ↗

A printable bedside figure for the unit and the Atom: a dragon on a rock, joined by printed dowels and dovetail keys without screws. The unit lies in the dragon's openwork head. The Atom sits in a cave in the rock, where a hollow plunger presses its button and lets its LED glow through. The Grove ribbon runs up a hollow core through the body and neck, and the USB-C cable through a tunnel in the rock. The cave can be on the dragon's left or right.

What goes where: the cave half with the four dowel holes labelled by pin length, the Atom on the plunger and the unit in the head; the closed figure with the two keys sliding in from below, the long key into the rock's back face and each wing's peg into its shoulder socketOpen full-size image ↗

The first build printed the halves, the wings and the keys. Its dowels came off the bed: they now lie on a wider flat with a brim. Its wings were loose in 4 mm sockets: the pegs now go 8 mm deep. Neither fix has been printed yet.