M5Stack Unit CO2L: wiring, firmware and enclosure
M5Stack's Unit CO2L (SKU U104) is a Sensirion SCD41 photoacoustic CO₂ sensor that also reads temperature and humidity. It comes with a 20 cm Grove cable and hangs from an M5Stack Atom Lite, which reports it to Home Assistant over ESPHome. One unit gives one room a CO₂ reading, and the Ramka shows that room on its Air page (SPEC-042). Device file: m5stack-unit-co2l.yaml.
Wiring
Plug the unit's Grove cable into the Atom Lite's Grove port. It needs no other wiring.
| Atom Lite Grove pin | signal | ESPHome |
|---|---|---|
| 5V | power (the unit regulates to 3.3 V) | |
| G | ground | |
| G26 | I²C SDA | sda: GPIO26 |
| G32 | I²C SCL | scl: GPIO32 |
Keep the unit at the end of its cable, away from the Atom. The Atom's warmth raises the unit's own temperature reading.
Firmware
The catalog has no package for the unit yet. Add this to the Atom's ESPHome device file, next to
whatever the node already runs (a bermuda-presence proxy, for example):
substitutions:
altitude: 300m # the room's height above sea level, for the pressure compensation
i2c:
id: grove_i2c
sda: GPIO26
scl: GPIO32
sensor:
- platform: scd4x
id: co2_unit
i2c_id: grove_i2c
altitude_compensation: ${altitude}
automatic_self_calibration: true
update_interval: 60s
co2:
name: CO2
temperature:
name: CO2 unit temperature
disabled_by_default: true # the unit's own air, warmed by the Atom
humidity:
name: CO2 unit humidity
disabled_by_default: true
api:
actions:
- action: calibrate_co2
variables:
co2_ppm: int
then:
- scd4x.perform_forced_calibration:
value: !lambda 'return co2_ppm;'
id: co2_unit
Name the CO₂ entity in the Ramka's air input as one room, for example
{label: Bedroom, room: bedroom, co2: sensor.<node>_co2}. With climate-air 0.3.1 or later, the
room's air: {co2: sensor.<node>_co2} in the home inputs adds the CO₂ limits (fair and poor),
which the Ramka settings dashboard changes.
After the first start
- Accuracy (Sensirion datasheet): ±(50 ppm + 2.5 %) up to 1000 ppm and ±(50 ppm + 3 %) up to 2000 ppm; specified to 5000 ppm.
- Self-calibration: it assumes the room reaches outdoor air, about 425 ppm, once a week. Treat the first week's readings as provisional.
- A room that is never aired: set
automatic_self_calibration: falseand calibrate by hand a few times a year. Run the unit for 3 minutes at a wide-open window, then call the node'scalibrate_co2action withco2_ppm: 425.
Enclosure
A printable bedside figure for the unit and the Atom: a dragon on a rock, joined by printed dowels and dovetail keys without screws. The unit lies in the dragon's openwork head. The Atom sits in a cave in the rock, where a hollow plunger presses its button and lets its LED glow through. The Grove ribbon runs up a hollow core through the body and neck, and the USB-C cable through a tunnel in the rock. The cave can be on the dragon's left or right.
- How to print and assemble it: the test cuts and fit coupon to print first, the parts, print settings, assembly, measurements and what a print has not confirmed yet.
- Bambu Studio projects (P2S, settings applied). Halves with the cave on the dragon's left: cave half, other half; with the cave on its right: cave half, other half. Shared parts: right wing, left wing, plunger, dowels, bottom key (print two), back key.
- STL for other slicers: the same parts in the folder's
light_left/,light_right/andstl/. - Parametric source (OpenSCAD) and build script.
The first build printed the halves, the wings and the keys. Its dowels came off the bed: they now lie on a wider flat with a brim. Its wings were loose in 4 mm sockets: the pegs now go 8 mm deep. Neither fix has been printed yet.